Difference between revisions of "Complete list"

From Gw-qcd-wiki
Jump to: navigation, search
(Ensembles)
Line 47: Line 47:
 
|+  
 
|+  
 
! scope="col" | Description  
 
! scope="col" | Description  
! scope="col" | Set of 3 full QCD gauge ensembles <br>with the x-direction elongated.
+
! scope="col" | Set of 4 full QCD gauge ensembles <br>with the x-direction elongated.
 
|+
 
|+
 
! scope="row" | Owner  
 
! scope="row" | Owner  
| <div align="center">  Craig, Kevin, Mike and Dehua </div>
+
| <div align="center">  Andrei, Craig, Kevin, Mike and Dehua </div>
 
|+  
 
|+  
 
! scope="row" | Location  
 
! scope="row" | Location  
|  <div align="center">  impact cluster<br>/mnt/data3/craigp/nHYP-beta-kappa-study </div>
+
|  <div align="center">  impact cluster<br>/mnt/data3/craigp/gwu-ensembles/clover-dyn-elong/kentucky/220mev (originally at /mnt/data3/craigp/nHYP-beta-kappa-study) </div>
 
|-  
 
|-  
 
! scope="row" |   
 
! scope="row" |   
 
Volume
 
Volume
|  <div align="center">  <math> N_x=24, 28, 32\times 24^2\quad N_t=64  </math> and $16^3\times32$</div>
+
|  <div align="center">  <math> N_x=24, 28, 32, 48\times 24^2\quad N_t=64  </math> and $16^3\times32$</div>
 
|-  
 
|-  
 
! scope="row" |   
 
! scope="row" |   

Revision as of 14:10, 6 May 2019

Ensembles

$ \def\fm {\,{\tt fm}} \def\MeV {\,{\tt MeV}} \def\GeV {\,{\tt GeV}} \def\degC{\,{^\circ{\tt C}}} \def\degK{\,{\tt K}} $

Description Set of 3 full QCD gauge ensembles
with the x-direction elongated.
Owner
Craig Pelissier October, 2011
Location
impact cluster
/mnt/data3/craigp/gwu-ensembles/clover-dyn-elong
the $16^3\times 32$ configs at /mnt/data3/craigp/nHYP-beta-kappa-study

Volume

\( N_x=24, 30, 48\times 24^2\quad N_t=48 \) and $16^3\times 32$

Parameters

\(\beta = 7.1\quad\kappa=0.1282 \)
\( a=0.1255(7) \text{ fm} \quad m_{\pi}=304(2) \text{ MeV}\)

num. configs

300 per ensemble, 5 trajecs between configs.
for $16^3\times32$ we have 149. all these configs are thermalized.

Action

clover-nhyp-smeared
$\alpha_0=0.75\;\alpha_1=0.6\;\alpha_2=0.3\; u_0 = 0.868$

Original Project

$\rho$-meson decon on asymmetrical boxes
Description Set of 4 full QCD gauge ensembles
with the x-direction elongated.
Owner
Andrei, Craig, Kevin, Mike and Dehua
Location
impact cluster
/mnt/data3/craigp/gwu-ensembles/clover-dyn-elong/kentucky/220mev (originally at /mnt/data3/craigp/nHYP-beta-kappa-study)

Volume

\( N_x=24, 28, 32, 48\times 24^2\quad N_t=64 \) and $16^3\times32$

Parameters

\(\beta = 7.1\quad\kappa=0.12838 \)
\( a=0.1255(7) \text{ fm} \quad m_{\pi}=220(2) \text{ MeV}\)

num. configs

1000(24), 800(28), 693(32) with 5 trajecs between configs.


for $16^3\times32$ we have 320. these configs are not thermalized.

Action

clover-nhyp-smeared
$\alpha_0=0.75\;\alpha_1=0.6\;\alpha_2=0.3\; u_0 = 0.868$

Original Project

$\rho$-meson decon on asymmetrical boxes

Be aware that there are some corrupted files. See the email below from Mike:

Date: Sat, 30 Aug 2014 11:05:44 -0400
Subject: Re: bad configs
From: Michael Lujan <mlujan@gwmail.gwu.edu>
To: Andrei Alexandru <aalexan@gwu.edu>
Cc: Dehua Guo <guodehua@gwmail.gwu.edu>

Hi Andrei,

the bad configs we found were for the 48 x 24^2 x 48 ensemble.  These
configurations 119-149 had very different plaquette values than the rest of
the ensemble. As such, I exclude them in the analysis.

Mike

UPDATE: the corrupted configurations were actually 120-150. They had plaquette values that were many sigmas away from the average from the other configurations. Moreover, the plaquette values disagreed with the values that were recorded in the log files at generation time. Most likely, a mistake was made when the configurations were renamed. I regenerated 30 configurations starting from 120 and replaced them in the directory /mnt/data3/craigp/gwu-ensembles/clover-dyn-elong/kentucky/300mev/nx48 on cray. (Andrei)