Description | Set of 3 full QCD gauge ensembles with the x-direction elongated. |
Owner | Craig Pelissier October, 2011
|
Location | impact cluster
/mnt/data3/craigp/gwu-ensembles/clover-dyn-elong the $16^3\times 32$ configs at /mnt/data3/craigp/nHYP-beta-kappa-study |
---|---|---|---|---|---|
Volume |
\( N_x=24, 30, 48\times 24^2\quad N_t=48 \) and $16^3\times 32$
| ||||
Parameters |
\(\beta = 7.1\quad\kappa=0.1282 \)
\( a=0.1255(7) \text{ fm} \quad m_{\pi}=304(2) \text{ MeV}\) | ||||
num. configs |
300 per ensemble, 5 trajecs between configs.
for $16^3\times32$ we have 149. all these configs are thermalized. | ||||
Action |
clover-nhyp-smeared
$\alpha_0=0.75\;\alpha_1=0.6\;\alpha_2=0.3\; u_0 = 0.868$ | ||||
Original Project |
$\rho$-meson decon on asymmetrical boxes
|
Description | Set of 3 full QCD gauge ensembles with the x-direction elongated. |
Owner | Craig, Kevin, Mike and Dehua
|
Location | impact cluster
/mnt/data3/craigp/nHYP-beta-kappa-study |
---|---|---|---|---|---|
Volume |
\( N_x=24, 28, 32\times 24^2\quad N_t=64 \) and $16^3\times32$
| ||||
Parameters |
\(\beta = 7.1\quad\kappa=0.12838 \)
\( a=0.1255(7) \text{ fm} \quad m_{\pi}=220(2) \text{ MeV}\) | ||||
num. configs |
1000(24), 800(28), 693(32) with 5 trajecs between configs.
| ||||
Action |
clover-nhyp-smeared
$\alpha_0=0.75\;\alpha_1=0.6\;\alpha_2=0.3\; u_0 = 0.868$ | ||||
Original Project |
$\rho$-meson decon on asymmetrical boxes
|
Be aware that there are some corrupted files. See the email below from Mike:
Date: Sat, 30 Aug 2014 11:05:44 -0400 Subject: Re: bad configs From: Michael Lujan <mlujan@gwmail.gwu.edu> To: Andrei Alexandru <aalexan@gwu.edu> Cc: Dehua Guo <guodehua@gwmail.gwu.edu> Hi Andrei, the bad configs we found were for the 48 x 24^2 x 48 ensemble. These configurations 119-149 had very different plaquette values than the rest of the ensemble. As such, I exclude them in the analysis. Mike
UPDATE: the corrupted configurations were actually 120-150. They had plaquette values that were many sigmas away from the average from the other configurations. Moreover, the plaquette values disagreed with the values that were recorded in the log files at generation time. Most likely, a mistake was made when the configurations were renamed. I regenerated 30 configurations starting from 120 and replaced them in the directory /mnt/data3/craigp/gwu-ensembles/clover-dyn-elong/kentucky/300mev/nx48 on cray. (Andrei)